Loading...
Customer support

Marie Vašáková & Kateřina Veselská
are available from 7 00 to 18 00

Contact us
Technical support

Ing. Vojtěch Dědic
is available from 7 00 to 18 00

Contact us
Infoline - working days: 7 00am - 6 00pm
+420 565 777 111
This concept introduces dual polypropylene walls with resistance to water temperatures up to 60°C. It brings innovation in the neck design and the new shape of the seal. Constructions with natural pressure, combined hygiene equipment and rainwater mains. This system is used for common house sewage and for draining roads and highways.
Magnacor
  • Dvojité jadro

HEAVY DUTY RESISTANCE

The Magnacor system is manufactured in diameters ranging from 200 to 600 mm; its unrivalled properties derive from the material, copolymer from block polypropylene. At the same time, the system meets all future ecology standards and requirements.

HIGH DURABILITY AND TOUGHNESS, RESISTANCE TO ABRASION

The Magnacor sewage pipes and fittings are made from polypropylene (PP). Their special properties include smooth, homogenous inner and grooved outer walls with high ring stiffness, which make them the perfect choice for underground installations with higher peak pressures, such as highway roads, extreme depths or areas with a high level of groundwater. High mechanical resistance at subzero temperatures up to -20°C.

CLASS SN 8 TOUGHNESS

Due to the dual walls, the value of the ring stiffness of the Magnacor pipes and fittings amounts to SN 8. Therefore, the system is applicable for founding constructions in urban development areas or city centres.

WATER- AND GAS TIGHTNESS

The Magnacor sewage piping is:
water tight - at positive and negative pressure of 0.05 MPa
, gas tight - at positive and negative pressure of 0.05 MPa

Read more

EASY CONNECTION AND MODIFICATION

Optional connection to sewage systems with smooth walls. Optional modification of parts to any lengths, easy connection using a wide selection of fittings not only of the Magnacor range. As the pipes deliver a low weight and grooved outer layer, the handling and positioning in the trench is easier than in other sewage systems. There is 50% reduction in the force required to join the pipes. Easy transportation and fewer risks towards work safety during on-site installation. The pale grey colour of the inner wall provides excellent conditions for TV monitoring and inspection.

EXCELLENT SMOOTHNESS, HIGH ELASTICITY

The hydraulic smoothness of the inner piping wall allows for high flow rates of the transported media (prevents formation of deposits within the pipe), as well as the lower pitch application of the pipe (reducing the extent of groundwork). Excellent transfer of static load (tall embankments of roads, etc.) and dynamic load (e.g. high levels of road traffic: highways, high-speed roads, etc.)

Maximal operating temperatures can be found in individual catalogues of waste and sewage systems and sealing.

Sealing Area of application- temperatures
SBR (at the producer /within the range of Work) cca. -50°C up to +100°C
EPDM cca. -50°C up to +150°C
NBR (can be ordered separately) cca. -30°C up to +100°C

SBR Improved abrasion resistance and age resistance, good resistance against operating liquids
EPDM Excellent fastness to abrasion, ageing and fastness to most of operating liquids
NBR Versatile material. Sealing for contact with mineral oil or fuels. Poor resistance against ozone and weather resistance.

Our KG-System (PVC)® products are manufactured in classes SN 4 and SN 8, KG 2000 . Polypropylene® products are manufactured in the class SN 8 and MAGNACOR in the class SN8.

The sealing of systems BL, DD and Euro L Spezial are resistant against water with maximal volume of chlorine 0,6 mg/l.

„Placement in the area of ground water is possible only if it is ensured that the embankment material is not dislocated and shifted (e.g. embedding the fine gravel in concrete to the filtration layer)".

„During works in the area of ground water it is necessary to ensure that the bearing/supporting layer of placement does not contain water during the construction work implementation"

„The zone of pipework must be protected against each predictable change of bearing capacity, stability or the bed when such change can be a result of the ground water action for example".

Be so kind and contact us if you have doubts about suitability of the sewage piping placement. In such case we will carry out an analysis of structure.

We have the “leak tightness at external over-pressure” test record of the manufacturer of sealing rings at our disposal. The manufacturer is the firm M.O.L. and the test record is dated 14th July 2004). The test was conducted against the external pressure action in the height of 0,5 bar (5m of water column).

No, it cannot. 
Among other things, this provision serves for elimination of the backwater formation and formation of retained amount inside the system.

No, it is not. It is not allowed to take the piping of the rain water and sewage water inside the building together. The piping can be directed into the joint piping only outside the buildings (near the connecting channel on the boundary of the property).

The exception will become valid if the border development is concerned. In such case it is permissible that the rain water piping and sewage water piping is drained together inside the building.

The pipes with slide-in sleeves / couplings are usually placed in such manner that the sharp end is in direction of flowing. The sharp end is sliding into the sleeve / coupling.

The quote from Manual of plastic pipes (4th issue, paragraph 3.4.4 Construction of the sewage water channels and piping, page 463)

Thus the piping placement in direction of flowing is clearly defined.

If you have any questions
or you are interested in this system
Contact Us.

Contact Us

Read the arguments
why to invest
in plastic piping.

Why plastic piping

Are you lost?
See comparasions
and usage solutions.

Product lines comparasion
Cookies help us deliver our services. By using our services, you agree to our use of cookies. Learn more